NCC Product Home   Please Contact us for pricing

Models DNC-T2003 thru DNC-T2032
 

AC Input, Pulse Cleaning of Bag House Dust Collectors


DNC-T2020 shown

Operating Logic
Operating Logic: The control can function in 2 modes:

Continuous Mode: The pressure switch terminals are shorted. Upon application of input voltage, the control activates output #1 after the preset off time. It will continue to activate outputs sequentially until input voltage is removed.

On Demand Mode: The pressure switch terminals are connected to an isolated set of contacts of a differential pressure switch. The control will activate the outputs sequentially whenever the pressure switch contacts are closed. When the pressure switch contacts open, the output sequencing stops. Re-closing of the contacts will cause the control to resume activating the outputs.

Program wire allows the user to select the maximum number of outputs to be activated.

Note: Controls are shipped with jumper across pressure
Features
  • UR File #E65038
  • Digital Timing Circuitry: Allows for stable timing from -40°F to 150°F temperature range
  • Pulse Time: Line synchronized to eliminate 8 milliseconds triac turn off variation
  • 10 Amp-400/600V Output Triacs: For maximum protection against output shorts. 200 VA load rating.
  • RTV Coating: Conformally coated for protection against vibration, humidity and contamination
  • 2 Modes of Operation: Can be operated continuously or "on demand" via external pressure switch
  • Field Selectable: For numbers of outputs required
  • LED Indicators: For compartment being cleaned indication
  • Rugged Timing Adjustments: Large stable potentiometers are used for "on" and "off" time adjustments
  • Metal Chassis Provided: For mounting directly into NEMA-4 box
  • Timer Life Tested for 24 Hours: To eliminate field failures
  • Input Protection: 30 joule metal oxide varistor
  • One Year Warranty: Warranted to be free from defects in materials or workmanship for One Year from date of purchase
  • Made in USA
Specifications
Time Delay
On-Time: Adjustable from 50 to 500 milliseconds
Off-Time: Range A - adjustable from 1.5 to 30 seconds; Range B - adjustable from 8.5 to 180 seconds
Note: Range S designates customer specified time range. Consult factory for parameters
Repeatability: ± 3% over temperature and voltage ranges

Input
Operating Voltage:
   120 ± 10%, 220 ±10% VAC
Frequency: 50/60 Hz
Power Consumption: 2 VA Max.
Output
Type: Solid-state switch (Triac)
Switch Rating: 200 VA maximum per output

Protection
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 Amp. fuse

Environmental
Operating Temperature: -40°C to 66°C
Storage Temperature: -40°C to 70