General Description: The NCC Series of
Solid State Power Relays provide a highly reliable means of switching a variety of AC
loads up to 40 Amps. Snubber circuitry is included with each unit for high dv/dt
applications and inductive loads.
Use of rugged output devices provides significant increases in turn-on surge capability.
Two input control voltage ranges are available in either Form A (SPST-NO) or Form B
(SPST-NC) output configurations.
File #E164906
CSA Certified File #LR701222
24 to 330 VAC Load Voltage
4000 Volt Isolation
Optically Coupled
Epoxy Filled
Capable of Being Switched By a Single CMOS Gate
Built In Snubber
100% Life and Surge Tested
Capable of Switching Inductive Loads of 0.5 Power
Factor
Zero Crossing or Random Turn On Models Available
Made in U.S.A.
Specifications for 3 - 32
Volt Control Input Solid State Relays
Max. Load Current *
10 Amps
25 Amps
25 Amps
25 Amps
40 Amps
Part Number
SNC-R2010-502
SNC-R2025-502
SNC-R2025-507
SNC-R2025-517
SNC-R2040-502
Max. Surge Current
100 Apk,16.6 mS
250 Apk,16.6 mS
370 Arms,8.3 mS
370 Arms,8.3 mS
650 Apk,16.6 mS
Max. On State Voltage Drop
1.65 VAC (RMS)
1.65 VAC (RMS)
1.5 VAC (RMS)
1.5 VAC (RMS)
1.5 VAC (RMS)
Min. Off State dv/dt (static)
200 V/µS
200 V/µS
500 V/µS
500 V/µS
500 V/µS
Thermal Resistance Junction to Case
(point A)
1.48 °C/Watt Tj max.=100 °C
1.05 °C/Watt Tj max.=100 °C
1.3 °C/Watt Tj max.=110 °C
1.3 °C/Watt Tj max.=110 °C
.65 °C/Watt Tj max.=100 °C
Input Impedance
1500 ohms ±5%
1500 ohms ±5%
1700 ohms ±5%
1700 ohms ±5%
1500 ohms ±5%
Turn Off Voltage
1 VDC min.
1 VDC min.
2 VAC/DC max.
3 VAC/DC max.
1 VDC min.
Turn On Voltage
3 VDC max.
3 VDC max.
3 VAC/DC min.
2 VAC/DC max.
3 VDC max.
Turn On Type
Zero Crossing
Zero Crossing
Random
Random
Zero Crossing
Output Form
S.P.S.T.- N.O.
S.P.S.T.- N.O.
S.P.S.T.- N.O.
S.P.S.T.- N.C.
S.P.S.T.- N.O.
Control Voltage Range
3 - 32 VDC
3 - 32 VDC
3 - 30 VAC/DC
3 - 30 VAC/DC
3 - 32 VDC
Specifications for 70 - 280
Volt Control Input Solid State Relays
Max. Load Current *
10 Amps
25 Amps
25 Amps
25 Amps
40 Amps
Part Number
SNC-R2010-505
SNC-R2025-505
SNC-R2025-501
SNC-R2025-511
SNC-R2040-505
Max. Surge Current
100 Apk,16.6 mS
250 Apk,16.6 mS
370 Arms,8.3 mS
370 Arms,8.3 mS
650 Apk,16.6 mS
Max. On State Voltage Drop
1.65 VAC (RMS)
1.65 VAC (RMS)
1.65 VAC (RMS)
1.65 VAC (RMS)
1.5 VAC (RMS)
Min. Off State dv/dt (static)
200 V/µS
200 V/µS
500 V/µS
500 V/µS
500 V/µS
Thermal Resistance Junction to Case
(point A)
1.48 °C/Watt Tj max.=100 °C
1.05 °C/Watt Tj max.=100 °C
1.3 °C/Watt Tj max.=110 °C
1.3 °C/Watt Tj max.=110 °C
.65 °C/Watt Tj max.=100 °C
Input Impedance
40 Kohms ±5%
40 Kohms ±5%
56 Kohms ±5%
56 Kohms ±5%
40 Kohms ±5%
Turn Off Voltage
20 VAC min.
20 VAC min.
30 VAC max.
70 VAC min.
20 VAC min.
Turn On Voltage
90 VAC max.
90 VAC max.
70 VAC max.
30 VAC max.
90 VAC max.
Turn On Type
Zero Crossing
Zero Crossing
Random
Random
Zero Crossing
Output Form
S.P.S.T.- N.O.
S.P.S.T.- N.O.
S.P.S.T.- N.O.
S.P.S.T.- N.C.
S.P.S.T.- N.O.
Control Voltage Range
90 - 280 VAC
90 - 280 VAC
70 - 140 VAC
70 - 140 VAC
90 - 280 VAC
General Specifications -
Solid State Relays
Max. Load Current *
10 Amps
25 Amps
25 Amps
25 Amps
40 Amps
Model Numbers
SNC-R2010-502
SNC-R2010-505
SNC-R2025-502
SNC-R2025-505
SNC-R2025-501
SNC-R2025-507
SNC-R2025-511
SNC-R2025-517
SNC-R2040-502
SNC-R2040-505
Max. Peak Transient Voltage
600 Vpk
600 Vpk
600 Vpk
600 Vpk
600 Vpk
Output Voltage Range
24-330 VAC
24-330 VAC
48-300 VAC
48-300 VAC
24-330 VAC
Max. Off State
Leakage Current
8 mA
@330 VAC (RMS)
8 mA
@330 VAC (RMS)
7.2 mA
@300 VAC (RMS)
7.2 mA
@300 VAC (RMS)
8 mA
@330 VAC (RMS)
Operating Temp. Range
-40 to 100 °C
-40 to 100 °C
-40 to 80 °C
-40 to 80 °C
-40 to 100 °C
Storage Temp. Range
-40 to 100 °C
-40 to 100 °C
-40 to 65 °C
-40 to 65 °C
-40 to 100 °C
Dielectric Strength @60
Hz
between Input / Output
between Input / Base
between Output / Base