Time Delay
Adjustment: Knob, factory fixed on special order (Minimum order required)
Range: 50 mS to 1 hour in 10 ranges
Repeatability: ± 1% at constant temperature
Accuracy: Maximum time -0%, +10%;
Minimum
time +0%, -50%
Reset Time: 50 milliseconds maximum
Input
Operating Voltage: 24, 120 VAC; 12, 24 VDC ± 10% (D.C. models have reverse
polarity protection. Unfiltered input voltage to them must be full-wave rectified)
Power Consumption: 3 VA maximum
Frequency: 50/60 Hz
Output
Type: Relay Contacts, D.P.D.T. (2 form C)
Silver Cad. Oxide material
Rating: 10 amp. max. resistive at 240 volts A.C
100 mA at 5 VDC min. Load current
Life: Mechanical -10,000,000 operations
Full Load - 500.000 operations |
Protection
Transient Voltage: 12 and 24 volt timers are protected by an 8.8 joule metal oxide
varistor; 120 volt timers are protected by a 30 joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS minimum at 60 Hz between input and outputs and
between outputs
Mechanical
Termination: 8-pin plug-in base
Mounting: Socket Mount - Part Number MSO-0008P-012
Environmental
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C |