Programmable process control SMD hot air rework system with built-in
vacuum pick up. Manual or Automatic operating modes - you decide.
The
FR-803 integrated temperature sensor allows for consistent and accurate
temperature control, and the unique air stream outlet design allows for
consistent temperatures of the hot air stream generated by the unit.
Item #: FR803-11
The Hakko FR-803 provides three programmable 3-step rework profiles that are
stored in the unit's memory, allowing for easy recall and consistent operation.
Use the lockout key card to enter temperature settings into the system
memory, then when the card is removed, all parameter settings are “locked” into
the system memory and cannot be changed without the key card. This feature
guards against an operator making accidental or unauthorized temperature
changes.
Built-in power save feature automatically turns the hot air stream off if the
unit has not been stopped for a pre-selected (30 or 60 minutes) amount of time.
The FR-803 also features:
Self-contained air source
Built-in vacuum pick-up
Two modes of operation
Manual: Simple operation
Auto: Programmable process control
Digital temperature display (°F or °C)
Digital hot air dwell time display
Variable airflow
Easy-to-read airflow meter
Auto cool-down mode automatically engages when the stop button is pressed
Compact design uses less work area than previous models
ESD safe by design
Specifications
Model
Hakko FR-803
Part
Number
FR803-11
Station
Total Power Consumption
120V - 430W
Station Power Consumption
30W (Stand-by
Mode: 4W)
Handpiece Power Consumption
400W
Pump
Type
Diaphragm pump
Pump
Capacity
5 to more than
20 l/min.
Control Temperature*
100 to 450°C
(212 to 842°F)
*measured at heater sensor
Operating modes
Manual and
Automatic
Timer
3 file/step
Handpiece Length
(w/o cord)
200 (L) mm (7.9
in)
Handpiece Weight (w/o cord)
200 g (0.44
lb.)
Outer Dimensions
160(W) x 145(H)
x 230(D) mm
[6.3(W) x 5.7(H) x 9.1(D) in.]
Weight
5.0 kg (11.02
lbs.)
Note: Specifications subject to change without notice
Contents
Name
Part Number
Quantity
FR-803 Station
n/a
1
Power cord
1
Handpiece holder
1
Pads:
Ø3,
Ø5,
Ø7.6
mm
2 each
Vacuum pipe control knob (L)
1
Control card
1
Manual
n/a
1
Note: Station does not include nozzles. Nozzles
must be purchased separately.