Contact EMSCO today to purchase your Fluke Digital Multimeter
and take advantage of the Lifetime Limited Warranty on selected models

Fluke Product Home

Fluke VR101S Voltage Event Recorder System
Specifications

Product Home - Features - VR101S resale pricing
General Specifications - Technical Specifications

General Specifications

Memory size 4000 events
Battery type 3.5V lithium (non-replaceable)
Battery life 7 years
Physical size 3.35 in x 2.65 in x 1.35 in
(85 mm x 68 mm x 35 mm)
Weight 4 oz (120g)
Warranty 1 year
Environmental Operating temperature
-40 to 160 °F (-40 to 70°C)
Relative Humidity
0 to 95% (non-condensing)
Safety CSA Certification pending, CSA-NRTL (to UL 3111) certification pending, Complies with requirements of EN61010-1:1993
Computer Hardware Requirements IBM PC or 100% compatible, with Windows 3.1 or Windows 95 installed and operating, at least one free RS-232 serial port, a pointing device (recommended), 2 MB hard drive space, 4 MB RAM (8 MB for Windows 95)

Technical Specifications

Electrical
(voltage versions, plug style, and manual languages are determined by country)
120V Version
Operating Range: 70V to 140V
Nominal Frequencies: 50 Hz or 60 Hz
Power Consumption: 2W
230V Version
Operating Range: 140V to 270V
Nominal Frequencies: 50 Hz or 60 Hz
Power Consumption: 3W
Sags, Swells and Outage Measurements 120V Version
Hot-to-neutral
Range: 0 to 200V rms
Accuracy: ±2V rms
Resolution: 1V rms
Neutral-to-ground
Range: 3 to 200V rms
Accuracy: ±2V rms
Resolution: 1V rms
230V Version
Hot-to-neutral
Range: 0 to 270V rms
Accuracy: ±2V rms
Resolution: 2V rms
Neutral-to-ground
Range: 3 to 150V rms
Accuracy: ±1V rms
Resolution: 1V rms
Transient Measurements* Hot-to-neutral
Range: 100 to 2500V peak
Accuracy: ±(10% reading +10V)
Resolution: 10V
Neutral-to-ground
Range: 50 to 2500V peak
Accuracy: ±(10% reading +10V)
Resolution: 10V
Phase angle
Range: 20° to 180°, 200° to 360°
Accuracy: ±1°
Resolution: 1°
Frequency Measurements Range: 45 to 65 Hz
Accuracy: ±0.1 Hz (3 cycles min)
Resolution: 0.1 Hz
Time Measurements
Events < 1 second
Hot-to-neutral
Accuracy: ±0.5 cycles
Resolution: 0.5 cycles
Neutral-to-ground
Accuracy: ±1 cycle
Resolution: 1 cycle
Events >= 1 second (time stamp) Accuracy: ±(2 sec/day + 8 sec)
Resolution: 8 sec

* Minimum pulse width: 1 µs