Contact EMSCO today to purchase your Fluke Digital Multimeter
and take advantage of the Lifetime Limited Warranty on selected models

Fluke Product Home

Fluke Fiber Optic Meter

Resale Pricing

Test Fiber Optic Cable with Your Digital Multimeter

The Fluke Fiber Optic Meter (FOM) helps you test and maintain fiber optic cable without having to buy a whole new meter. Plug the FOM directly into any DMM with a mV dc function and a 10 MOhms input impedance, such as the Fluke 87 and quickly and accurately verify fiber optic cable system loss. Light sources and patch cords sold separately.

 

  • The compact FOM plugs into your DMM and makes testing in tight spaces easy
  • A variety of light sources (FOS 850, FOS 1300, and FOS 850/1300) and patch cords (ST to ST, ST to FC, ST to SC, ST to SMA) let you get just what you need for testing different cable types and lengths
  • Highly accurate readings mean less work, less repeated testing
  • Input connector: fixed ST
  • Battery life: 16 hours minimum, 9V alkaline
  • LED low battery indicator
  • Operating temperature: 0°C to +40°C (32°F to +104°F)
  • Storage temperature: -20°C to +70°C (-4°F to +158°F)

Specifications

FOM
(Fiber Optic Meter)
Output: 1 mV per 1 dB
Application Range: 800-1600 nm
Acceptable Fiber Types: 9/125 to 100/140 µm
Operating Range: +3 to -50 dBm
Absolute Accuracy: ±0.25 dB
Relative Accuracy: ±0.15 dB
Repeatability: ±0.04 dB
Operating Temp/RH: 0° to 40°C (32°F to 104°F) up to 75% RH
FOS 850
(Fiber Optic Source)
Wavelength:
850 nm
±30 nm
Output Power: -20 dBm
Connector: ST
Stability: ±0.2 dB per 8 hours
Battery Type: 9V alkaline NEDA 1604A or IEC 6LR61
Battery Life: 24 hours typical
Operating Temp/RH: 0°C to 40°C (32°F to 104°F)
FOS 1300
(Fiber Optic Source)
Wavelength:
1300 nm
-40/+50 nm
Output Power: -20 dBm
Connector: ST
Stability: ±0.2 dB per 8 hours
Battery Type: 9V alkaline NEDA 1604A or IEC 6LR61
Battery Life: 24 hours typical
Operating Temp/RH: 0°C to 40°C (32°F to 104°F)
FOS 850/1300
(Fiber Optic Source)
Wavelength:
850 nm/1300 nm
±30 nm/-40/+50 nm
Output Power: -20 dBm
Connector: ST
Stability: ±0.2 dB per 8 hours
Battery Type: 9V alkaline NEDA 1604A or IEC 6LR61
Battery Life: 24 hours typical
Operating Temp/RH: 0°C to 40°C (32°F to 104°F)