Fluke 787 ProcessMeter
Comparison Chart
Specifications -
Pricing
Features
|
Fluke 787
ProcessMeter
|
Fluke 87 MultiMeter
|
| Counts (Basic |
4000 |
4000 |
| DC Volts |
Yes |
Yes |
| Accuracy DC Volts |
0.1% |
0.1% |
| True rms AC Volts |
to 1 kHz |
to 20 kHz |
| Counts (Current) |
30000 |
4000 |
| AC/DC Current Measure |
to 1 A (440 mA continuous) |
to 10 A |
| Accuracy mA |
0.05% |
0.2% |
| Current Source |
to 24 mA |
N/A |
| Current Simulate |
to 24 mA |
N/A |
| Current Ramp and Step |
to 24 mA |
N/A |
| Secondary Display |
Percent of Span Display |
Bar Graph |
| Ohms |
Yes |
Yes |
| Continuity |
Yes |
Yes |
| Frequency |
to 20 kHz |
to 20 kHz |
| Safety |
1000 V Cat III |
1000 V Cat III |
| Backlight |
Yes |
Yes |
| Diode Test |
Yes |
Yes |
| Relative Measurements |
Yes |
Yes |
| Min/Max/Avg recording |
Yes |
Yes |
| Touch Hold |
Yes |
Yes |
| 1 ms Peak Hold |
No |
Yes |
| Duty Cycle |
No |
Yes |
| Conductance |
No |
Yes |
| Capacitance |
No |
Yes |
Features
|
Fluke
ProcessMeter
|
Typical Loop
Calibrator
|
| Source mA |
Yes |
Yes |
| Simulate mA |
Yes |
Yes |
| Measure V |
1000 V |
100 V |
| Display |
mA AND % span |
Ma OR % of span |
| Span |
0-20 mA or 4-20 mA |
4-20 mA |
| Batteries |
One 9 Volt |
Three 9 Volt |
| Battery Life |
12 hours source
50 hours measure |
30 hours source
150 hours measure |
| Battery Replacement |
external door |
disassemble instrument |
| mA Resolution |
1 uA |
10 uA |
| Auto ramp/Auto step |
Yes |
No |
| Instant Check Points |
0, 25, 50, 75, 100% |
0, 100% |
| mA Protection |
150 V without fuses |
135 V without fuses |
| Min/Max/Rel/Hold |
Yes |
No |
|
|
|
|