Fluke 1520 MegOhmMeter
Specifications
Product Home
- Specifications
- Models, Options &
Accessories - 1520
Pricing
Technical Data
- Safety Specifications
- Environmental Specifications
Mechanical & General
Specifications
|
Technical Data
|
| Auto ranges |
Range: 4.000 MΩ, 40.00 MΩ, 400.0 MΩ, 4000 MΩ,
Accuracy: To 100 MΩ: 2% + 2 counts Over 100 MΩ: : 10% + 2 counts +1%/GΩ:
Resolution: 0.001MΩ; to 10 MΩ; |
| Test voltages |
Range:250V, 500V, 1000V
Accuracy:+20%, -0% |
| Max measurement current |
1 mA |
| Audible/visible voltage warning |
³ 30V ac or dc |
| Lo-Ohms Resistance |
Range:O to 40.00Ω
Accuracy:2% + 2 counts
Resolution: 0.01Ω |
| Lo-Ohms Analog bar graph |
0 to 100Ω |
| Lo-Ohms Audible/visible voltage
warning |
³ 30V ac or dc |
| Resistance |
Range: 4 k
Ω
Accuracy: 2% + 2 counts
Resolution: 1Ω |
| Analog bar graph |
0 to 10kΩ |
| Voltage |
Range: 0 to 600V ac (50/60 Hz),
0 to 600V dc
Accuracy: 2% + 2 counts
Resolution: 1V |
|
Safety Specifications
|
| Electrical safety |
Meets IEC 1010-1 and EN 61557 |
| Protection class |
Pollution degree II |
| Overvoltage category |
IEC 1010-1 CAT III 600V |
| Agency Approvals |
UL, CSA, TUV (pending) |
|
Environmental Specifications
|
| Operating Temperature |
-10°C to +50°C |
| Storage Temperature |
-40°C to +70°C |
| Humidity (Without Condensation) |
75% RH (40°C) |
| Dust/water resistance |
IP42 per IEC 529 |
| Operating Altitude |
2,500 meters |
|
Mechanical & General Specifications
|
| Battery Check Function |
Indicates remaining percent of charge |
| Size |
241 x 108 x 72mm (9.5 x 4.25 x 2.85 inches) |
| Weight |
1.1 kg (2.5 lbs) |
| Batteries |
4 C size 1.5V alkaline |
| Warranty |