The 2650 are
high-performance spectrum analyzers providing excellent performance and
functions perfect for many different applications.
It is a compact,
lightweight and inexpensive unit that is ideal for testing W-CDMA, CDMA,
GSM, PDC, PHS, Wireless LAN and Bluetooth systems. There are many
accessories available for the 2650 and some of them may be necessary for
your application, so please view the available accessories before
ordering.
Included accessories are BC 2650, LC 2650, BP 2650, accessory
pouch, fuse and instruction manual. Features:
Channel power measurement
Adjacent channel power measurement
Occupied bandwidth measurement
Electric field strength measurement (with optional dipole antennas)
Magnetic field strength measurement (with optional PR 26M)
Min/Max hold
Average and over write mode
Marker measurement
Peak search
Auto tuning
Auto range
Save/Load
Hard copy of display (with optional PT 2650)
Specifications
Frequency
section
Frequency
range
50kHz
to 3.3GHz
Center
frequency
Setting resolution
100kHz
Allows rotary encoder, numeric key and function key
less
than -40dBc (50kHz to100MHz)
less than -45dBc (100MHz to 3.3GHz)
Amplitude
section
Reference level
Setting range
+10
to -40dBm (1dB step)
Accuracy
within
±0.8dB ±1dot
(center frequency : 100MHz, RBW : 3MHz, VBW : OFF, ATT : 0dB, 23
±5°C)
Unit
dBm,
dBV, dBmV, dBµV, dBµV/m, dBµA/m
(dBµV/m
and dBµA/m is used the measuring function)
Average noise level
-110dBm
(typical, center frequency : 100MHz RBW : 3kHz, VBW : 100Hz)
Frequency
Characteristic
within
±2.0dB ±1dot (50kHz to100MHz)
within ±1.0dB ±1dot (100MHz to 3.3GHz)
Input impedance
50Ω
Input VSWR
less
than 2.0
Input attenuator
Operating range
0
to 25dB (1dB step), coupled with reference level
Switching error
within
±0.6dB
RBW switching error
within
±0.6dB
Display
resolution
0.4dB
(10dB/div), 0.08(2dB/div)
Display
dot number
200dot
Display scale
Scale
10dB
/ div, 2dB / div
Accuracy
within
±0.2dB / 2dB ±1dot
within ±0.8dB / 10dB ±1dot
within ±1.6dB / 70dB ±1dot
Input damage level
+20dBm
(CW average power), 25VDC
Input connector
SMA
(J)
Sweep
section
Sweep time
Setting range
10ms
to 30s (1-3step, frequency span : 0 to 2GHz) and AUTO
30ms to 30s (1-3step, frequency span : full span) and AUTO
Accuracy
within
±0.1% ±1dot ( frequency span : 0 to 2GHz)
within ±1.5% ±1dot ( frequency span : full span)
Trigger mode
AUTO
(frequency span : zero span)
Detection mode
Positive
peak, Negative peak, Sample
(when
sweep time is 10ms or 30ms, only Sample can be set)
Functions
Marker
NORM
:
displays
frequency (7 digits max) and level (4 digits max) at
marker point.
DELTA
:
displays
difference frequency and level between 2 markers.
Peak search
NORM
:
searches a
peak point within 10div. Available NEXT peak (10max).
ZONE
:
searches a
peak point within a zone designated by center and width.
Marker moves to a peak point each sweep.
Calculation
NORM,
MAX HOLD, MIN HOLD, AVERAGE, OVER WRITE
* MAX/MIN HOLD : 2 to 1024 times, AVERAGE : 2 to 256
Measuring
Channel
power, Adjacent channel power, Occupied frequency bandwidth,
Electric field strength (needs optional antenna), Magnetic field
strength (needs optional magnetic field probe) measurement.
AUTO tuning
When
pressing AUTO TUNE key, the maximum level spectrum within 3.3GHz
bandwidth is adjusted to center, and reference level, RBW, VBW
and sweep time are adjusted to optimum values.
Save / Load
Save
Saves
100 traces and 100 setups
Load
Loads
1 trace and 1 setup
General
Communication
Interface
RS-232C
Baud rate
2,400
to 38,400bps
Hard copy
Allows
direct hard copy with an optional printer
Display
Display
LCD
Backlight
CFL
backlight
Resolution
320
(H) × 240 (V) dots
Power source
Battery
Ni-MH
Battery
External DC source
Pin
jack, DC5V / 4A
Other
Operating temperature
0
to 40°C (Guaranteed at 23 ±10°C, without soft carrying case)
Operating humidity
less
than 40°C / 80%RH (Guaranteed at less than 33°C / 70%RH,
without soft carrying case)
Storage temperature
-20
to 60°C, less than 60°C / 70%RH
Dimensions
162
(W) × 70 (H) × 260 (D) mm (exclude projections and stand)