Specializing in high quality, cost-effective test and measurement products

B+K Product Home

Model 2630 - Spectrum Analyzer

Spectrum Analyzer Pricing

B+K 2630 Spectrum Analyzer

A great tool for professionals in the cable TV industry as well as in the telecommunication. It is a value packed service tool for signals up to 1.05GHz.

All three models are suitable for pre-compliance testing during development prior to third party testing. An optional near field sniffer probe set (PR 261) can be used to locate cable and PC board emission "hot spots" and evaluate EMC problems at the breadboard and prototype level.

The spectrum analyzer/sniffer probe combination is an excellent solution for RF leakage/radiation investigation, CATV/MATV system troubleshooting, cellular telephone/pocket pager test and EMI diagnostics.
  • 150kHz to 1.05GHz (1050MHz)
  • Dynamic Range 80dB (113dB with attenuation)
  • AM & FM demodulator included
  • 20 and 400 kHz resolution bandwidth
  • 150kHz/hour stability
  • Built-in tracking generator

Specifications

Frequency 1.05GHz (1050MHz)
Frequency range 0.15 MHz to 1.05GHz (1050MHz) (-3dB)
Center frequency display accuracy +-100kHz
Marker accuracy +-(0.1% span + 100 kHz)
Frequency display resolution 100 kHz (4 digit LED)
Frequency scanwidth 100kHz/div to 100MHz/div in 1-2-5 steps and 0Hz/div (Zero Scan)
Frequency scanwidth accuracy +-10%
Frequency stability Drift: < 150kHz/hour
IF Bandwidth (-3 dB) Resolution: 800 kHz and 20 kHz. Video-Filter on: 4 kHz
Sweep rate 43Hz
AMPLITUDE
Amplitude range -100dBm to + 13 dBm
Screen display range 80 dB (10 dB/div.)
Reference level -27 dBm to + 13 dBm (in 10dB steps)
Reference level accuracy +-2 dB
Average noise level -99dBm (12.5kHz BW)
Second and third harmonic <-75dBc
Third order intermod. -70dBc (two signals > 3MHz apart)
Log scale fidelity +-2dB (without attn.) 250MHz
IF gain 10 dB adjustment range
INPUT
Input impedance 50Ω
Input connector BNC
Input attenuator 0 to 40 dB (4 x 10 dB steps)
Input attenuator accuracy +1 dB
Maximum input level + 10 dBm, +-25 VDC (with 0 dB attenuation);
+20 dBm (with 40 dB attenuation)
TRACKING GENERATOR (Model 2630 & 2635)
Output level range -50 dBm to + 1 dBm (in 10dB steps and var.)
Output attenuator 0 to 40 dB (4 x 10 dB steps)
Output attenuator accuracy +-1 dB
Output impedance 50W (BNC)
Frequency range 0.15MHz to 1050MHz
Frequency response +-1.5dB
Radio Frequency Interference (RFI) <20dBc
GENERAL
Operating temperature 50 0 to 122 0 F (10 0 C to 50 0 C)
Display CRT. 6 inch, 8 x 10 div. internal graticule
Trace rotation Adjustable on front panel
Line voltage 90-260VAC, 50/60 Hz (125V, 400Hz)
Power consumption approx. 20W
Max. ambient temperature 14 0 to 104 0 F (-10 0 C to +40 0 C)
Protective system Safety Class 1 (IEC 348)
Weight approx. 13.2 lbs. (6.0 kg)
Dimensions (HxWxD) 4.9x11.2x15'' (125 x 285x380mm)
One Year Warranty
Accessories
SUPPLIED: Instruction Manual, Power Cord

OPTIONAL:
AT-21 Telescoping Antenna, PR-70 Active FET Probe, PR-261 Near-field Sniffer Probe, TE-26 50W feedthru termination, RM-26 19-inch
Rackmount Adapter, ZTF-1 50W to 75Ohm Adapter, LC-210A Carrying Case