Specializing in high quality, cost-effective test and measurement products

B+K Product Home

Model 2160A 60 MHz Analog Oscilloscope

Analog -  30MHz W/ 50MHz Frequency Counter | 30 MHz | 40 MHz | 60 MHz | 100 MHz
Digital - 20 MHz Analog/Digital | 150 MHz Analog/Digital | Selection Guide | Oscilloscope Pricing

  • 5mV/div sensitivity
  • 23 calibrated ranges-main time base
  • 23 calibrated ranges-delayed time base
  • Signal delay time
  • Component tester
  • Z axis input
  • Single sweep

60 MHz Analog Oscilloscope - Specifications

Specifications model
  2160A
VERTICAL AMPLIFIERS (CH 1 and 2)
Sensitivity 5mV/div to 1V/div x 5mag
Attenuator 1-2-5 sequence, plus x 5 gain step. Vernier control provide fully adjustable sensitivity between steps range 1/1 to at least 1/2.5
Accuracy +-3%, 5mV to 5V/div; +-5%, 1 mV, 2mV/div
Input Impedance 1M +-2%
Input Capacitance 25 pF +-10%
Frequency Response DC to 60 MHz
Rise Time 5.8ns (Overshoot <= 5%)
Operating Modes CH1, CH2, Dual, Alternate Chop
Polarity Reversal CH 2 invert
Maximum Input Voltage 400V (DC + AC Peak), 800 VAC p-p
SWEEP SYSTEM
Sweep Display Modes Main, Mix, Delay
Hold Off Time 5:1 continuously variable
Main Sweep
Sweep Speed 0.1us/div. to 2.0s/div. in 1-2-5 sequence, 23 steps
Accuracy +-3%
Variable Time Control 5:1, uncalibrated, continuously variable between steps
Sweep Magnification 10 x, +-10%, extended sweep speed up to 10ns/div
Delay Sweep
Sweep Speed 0.1us/div. to 2.0s/div. in 1-2-5 sequence, 23 steps
Accuracy +-3%
Sweep Magnification 10 x, +-10%, extended sweep speed up to 10ns/div
Delay Time Position Variable control to locate desirable waveform for extending
Triggering
Trigger Coupling AUTO, NORM, TV-V, TV-H
Trigger Source CH1, CH2, ALT, EXT, LINE
Slope +/-
HORIZONTAL AMPLIFIER
(Input through channel 2 input)
X-Y Mode CH 1: Y axis. CH 2: X axis
Sensitivity Same as vertical channel 2
Accuracy +-3%, Y axis: +-5% X axis
Input Impedance Same as vertical channel 2
Frequency Response DC: DC to 1 MHz (-3 dB). AC: 5 Hz to 2 MHz (-3 dB)
X-Y Phase Difference 3 0 at 50 kHz
Maximum Input Voltage Same as vertical channel 2
CH 2 Output (on rear panel)
Output Voltage 50 mV/div (nominal into 50 load)
Output Impedance Approximately 50 
Frequency Response 20Hz to 60MHz, -3dB into 50V
CRT
Type 6-inch rectangular with internal graticule
Display Area 8x10div (1 div = 1 cm)
Accelerating Voltage 12k
Phospor P31
Scale Illumination Continuously variable
Trace Rotation Electrical, front panel adjustable
COMPONENT TESTER
Components Tested Resistors, capacitors, inductors, and semiconductors
Test Voltage 6V rms maximum (open)
Test Current 11 mA maximum (shorted)
Test Frequency Line frequency (60 Hz in USA)
Other Specifications
Cal/Probe Compensation Voltage 2.0V p-p +-2% square wave, 1 kHz nominal
Sweep Output TTL level allows synchronization of external equipment with scope sweep
Intensity Modulation
Input Signal TTL level, intensity increasing with more negative levels
Input Impedance Approx. 1k
Usable Freq. Range DC to 5MHz
Maximum Input Voltage 5V (DC + AC peak)
Environment
Within Specified Accuracy 50 0 to 95 0 F (10 0 to 35 0 C), 85% maximum RH
Full Operation 32 0 to 122 0 F (0 0 to +50 0 C), 10 - 80% RH
Storage -22 0 to 158 0 F (-30 0 to +70 0 C), 10-90% RH
Power Requirements 110/120/220/240 V +- 10%, 50/60 Hz
Dimensions (HxWxD) 12.76 x 15.68x5.2'' (324x398x132 mm)
Weight 16.75 lbs. (7.6 kg)
Three Year Warranty
Accessories
SUPPLIED: Instruction Manual, Two PR-33A x1/x10 Probes or equivalent, AC Power Cord, Spare Fuse
OPTIONAL: PR-32A Demodulator Probe, PR-37A x1/x10/REE Probe, PR-100Ax100 Probe, PR-55 High Voltage x1000 Probe, LC-210A Carrying Case