| Specifications |
Models |
| |
1653A |
1655A |
| Voltage Adjustment Range |
0-150
VAC with input at 120 VAC |
| Output Isolation |
Leakage
less than 0.1 mA (25 0C, 50% RH) |
| Current Ranges |
0-2A |
0-2A, 0-4A |
| Maximum Current
(Isolated) |
2A continuous (0-130V) |
3A continuous, 4A
intermittent (0-130V) |
| Peak Current (inrush) |
N/A |
30A max. (inrush limited
to one cycle at 30A) |
| Voltage/Current Sensing |
Sine wave
average, calibrated in RMS |
| Meter Scale |
0-140VAC
0-2VAC |
0-240VAC
0-480VAC (voltage set at
120) |
| Leakage |
|
0-5000 uA
(expanded in 100-500 uA
portion, compressed to 5 mA full scale) |
| Metering |
3 1/2'' overrange
protected |
4 1/2 multicolor scales,
overrange protected |
| Meter Accuracy |
+-5% of full scale |
+-5% of full scale (volts
and current)
+-5% at 500 uA (leakage) |
| Soldering Iron Temp.
Control |
|
70 - 99% of power line
(100W max.) |
| Power Requirements |
120 VAC +- 10%, 60 Hz
300VA |
120 VAC +-10%, 60 Hz
600VA at Maximum Output |
Dimensions
(HxWxD) |
5.5x6.5x10.5''
(140x165x267 mm) |
10.5x5.7x12''
(267x145x305 mm) |
| Weight |
12 lbs. (5.5 kg) |
22 lbs. (10 kg) |
| |
One Year
Warranty |