10 steps in 1-2-5
sequence. Vernier control provides full adjustment between steps
Accuracy
+-3%, +-5% at x5
Input Resistance
1 M
+ 2%
Input Capacitance
25 pF +- 10pF
Frequency Response
5 mV to 5V/div: DC to 30
MHz (-3 dB)
X5: DC to 10 MHz (-3 dB)
Rise Time
12 ns (Overshoot <=
5%)
Operating Modes
CH 1: CH 1, single trace
CH 2
CH 2, single trace
ALT
dual trace, alternating
CHOP
dual trace, chopped
ADD
algebraic sum of CH 1 +
CH 2
Polarity Reversal
CH 2 only
Max. Input Voltage
400 V (DC to AC peak)
SWEEP SYSTEM
Operating Modes
Main, mix (both main
sweep and delay sweep displayed), or Delay (only delay sweep
displayed), X-Y
Main Sweep SpeeD
0.1 us/div to 2.0 s/div
in 1-2-5 sequence, 23 steps Vernier control provides fully
adjustable sweep time between steps
Accuracy
+-3%
Sweep Magnification
10X, +-5%
Delayed Sweep Speed
0.1 ms/div to 0.1 s/div
in 1-2-5 sequence, 23 steps
Holdoff
Continuously variable for
Main sweep up to 10 times normal
Delay Time Position
Continuously variable to
control percentage of display that is devoted to main and delay
sweep
TRIGGERING
Triggering Modes
AUTO (free run) or NORM,
TV-V, TV-H
Trigger Source
CH 1, CH 2, ALT, EXT,
LINE
Maximum External Trigger
Voltage
300 V (DC + AC peak)
Trigger Coupling
AC 30 Hz to 30 MHz
TV H Used for triggering
from horizontal syns pulses
TV H Used for triggering
from vertical syns pulses
TRIGGER
SENSITIVITY
Coupling
Bandwidth
Int
Ext
Auto
100Hz - 40MHz
1.5 div.
>=0.1Vp-p
Norm
100 Hz - 40 MHz
1.5 div.
>=0.1Vp-p
TV-V
DC - 1kHz
0.5 div
>= 0.05Vp-p
TV-H
1 kHz - 100 kHz
0.5 div
>= 0.05 Vp-p
HORIZONTAL
AMPLIFIER (Input through channel 1 input)
X-Y Mode
Switch selectable using
X-Y switch, CH 1: X axis CH 2: Y axis
Sensitivity
Same as vertical channel
2
Accuracy
Y-Axis: +-3%. X-Axis:
+-6%
Input Impedance
same as vertical channel
2
Frequency Response
DC to 1 MHz typical (-3
dB), to 6 div horizontal deflection
X-Y Phase Difference
3 0 or less at
50 kHz
Max. Input Voltage
Same as vertical channel
2
CRT
Type
Rectangular with internal
graticule
Display Area
8 x 10 div (1 div = 1 cm)
Accelerating Voltage
2 kV
Phosphor
P31
Trace Rotation
Electrical, front panel
adjustable
COMPONENT
TESTER
Components Tested
Resistors, Capacitors,
Inductors, and Semiconductors
Test Voltage
6V rms maximum (open)
Test Current
11 mA maximum (shorted)
Test Frequency
Line Frequency (60Hz in
USA)
Calibrating Voltage
1 kHz (+-10%) Positive
Square Wave, 0.2 V p-p (+-2%)
Other
Specifications
Within Specified Accuracy
50 0 to 95 0
F (10 0 to 35 0 C), <= 85% RH
Full Operation
32 0 to 104 0
F (0 0 to 40 0 C), <= 85% RH
Storage
-4 0 to 158 0
F (-20 0 to +70 0 C)
Power Requirements
Approximately 40 W
All other
operating specifications are the same as model 2120A
Dimensions (WxHxD)
7x14.5x14.25''
(180x370x440 mm)
Weight
Approximately 17.2 lbs.
(7.8 kg)
Three Year
Warranty
Accessories
SUPPLIED:
Instruction Manual, Two PR-33A x1/x10 Probes or equivalent, AC
Power Cord, Spare Fuse
OPTIONAL: PR-32A
Demodulator Probe, PR-37A x1/x10/REE Probe, LC-210A Carrying Case
Specifications
model
2120B
VERTICAL
AMPLIFIERS (CH 1 and CH 2)
Sensitivity
5 mV/div to 5 V/div, 1
mV/div to 1 V/div at X5
Attenuator
10 steps in 1-2-5
sequence. Vernier control provides full adjustment between steps.
Accuracy
+-3%, +-5% at X5
Input Resistance
1 M
+- 2%
Input Capacitance
25 pF +- 10pF
Frequency Response
5 mV to 5 V/div: DC to 30
MHz (-3 dB). X5: DC to 10 MHz (-3 dB)
Rise Time
12 ns (Overshoot <=
5%)
Operating Modes
CH 1: CH 1, single trace
CH 2
CH 2, single trace
ALT
dual trace, alternating
CHOP
dual trace, chopped
ADD
algebraic sum of CH 1 +
CH 2
Polarity Reversal
CH 2 only
Maximum Input Voltage
400 V (DC + AC peak)
SWEEP SYSTEM
Sweep Speed
0.1 us/div to 2s/div in
1-2-5 sequence, 23 steps. Vernier control provides fully
adjustable sweep time between steps.
Accuracy
+-3%
Sweep Magnification
10x
TRIGGERING
Triggering Modes
AUTO (free run) or NORM,
TV-V, TV-H
Trigger Source
CH 1, CH 2, ALT, EXT,
LINE
Maximum External Trigger
Voltage
300 V (DC + AC peak)
Trigger Coupling
AC 30 Hz to 30 MHz
TV H
Used for triggering from
horizontal sync pulses
TV V
Used for triggering from
vertical sync pulses
TRIGGER
SENSITIVITY
Coupling
Bandwidth
Int
Ext
Auto
100 Hz - 30 MHz
1.5 div.
100 mV
Norm
DC to 30 MHz
1.5 div
100 mV
TV V
20 Hz-1 kHz, 5
div
100 mV
TV H
1 kHz-100 kHz
.5 div
100 mV
HORIZONTAL
AMPLIFIER (Input through channel 2 input)
X-Y Mode
Switch selectable using
X-Y switch. CH 1: X axis
CH 2
Y axis
Sensitivity
Same as vertical channel
1
Input Impedance
Same as vertical channel
1
Frequency Response
DC to 1 MHz typical (-3
dB)
X-Y Phase Difference
Approximately 3'' at 50
kHz
Maximum Input Voltage
Same as vertical channel
1
CRT
Type
Rectangular with internal
graticule
Display Area
8x10 div (1 div = 1 cm)
Accelerating Voltage
2 kV
Phosphor
P31
Trace Rotation
Electrical, front panel
adjustable
Other
Specifications
Calibrating Voltage
1 kHz (+-10%) Positive
Square Wave, 2 V p-p (+-3%)
ENVIRONMENT
Within Specified Accuracy
50 0 to 95 0
F (10 0 to 35 0 C), <= 85% RH
Full Operation
32 0 to 104 0
F (0 0 to 40 0 C), <=85% RH
Storage
-4 0 to 158 0
F (-20 0 to +70 0 C)
Power Requirements
100/120/220/240 VAC +-
10%, 50/60 Hz, approximately 40 W.
Dimensions (WxHxD)
7x14.5x17.25'' (180 x 370
x 440 mm)
Weight
Approximately 17.2 lbs.
(7.8 kg)
Two Year
Warranty
Accessories
SUPPLIED:
Instruction Manual, Two PR-33A x1/x10 Probes or equivalent, AC
Power Cord, Spare Fuse
OPTIONAL: PR-32A
Demodulator Probe, PR-37A x1/x10/REE Probe, PR-100A x 100 Probe,
PR-55 High Voltage x1000 Probe, LC-210A Carrying Case